Rockfon® MediCare® Air

Specifically designed for use in pressurised healthcare environments where differential air pressure is required to prevent infection spreading eg. surgeries, recovery rooms, intensive care, etc.
Order Sample
Back

Color

White

ColorWhite
Color GroupWhites
NCSNCS S 0500-N
Light reflection85

Order Sample

Quantity:
1

Edge

Select an edge
Select an edge
A24
;
Back

Sound absorption details

Edge Thickness (mm) Suspension height (mm) αw NRC Sound absorption class (ISO) Sound curve
A24 edge icon 25 200 0,80 0,90 B
Sound curve

Sound absorption is measured in accordance with ISO 354.

Sound absorption data αp, αw and absorption class are calculated in accordance with ISO 11654. Sound absorption properties of islands and baffles are quantified by the equivalent sound absorption area Aeq expressed as m² per item.

Back
Sound curve

Other performances

Compare
Reaction To Fire Reaction To Fire A1 (EN 13501-1)
Light reflection and light diffusion Light reflection and light diffusion 85%
Humidity And Sag Resistance Humidity And Sag Resistance Up to 100% RH.
No visible deflection in high humidity
Surface Durability Surface Durability Enhanced durability and dirt resistance.
Cleaning Cleaning Vacuum, Damp cloth, Dry steam cleaning (twice a year), Chemical resistance: resistant to diluted solutions of ammonia, chlorine, quaternary ammonium and hydrogen peroxide
Hygiene Hygiene Stone wool provides no sustenance to microorganisms
Microbiological class M1 fulfilling the requirements of Zone 4 (very high risk) defined by NF S 90-351:2013. Tested with:
- Methicillin Resistant Staphylococcus Aureus (MRSA)
- Candida Albicans
- Aspergillus Brasiliensis
The bactericidal and fungicidal effect of dry steam cleaning meets the requirements of NF EN 14561 (> 5 log10) and NF EN 14562 (> 4 log10), meaning the disinfection is very effective.
Clean Room Classification Clean Room Classification 3
Bacteriological Class M1, NF S 90-351:2013
Air Pressure Air Pressure This solution is perfect for rooms where differential pressure is a needed requirement to stop infections from spreading outside the room. When used in combination with a HDC 2 (25 mm tile) or HDC 7 (40 mm tile) and 8 clips per 600 x 600mm tile, the high-performance membrane with sealed edges, and a closed neoprene foam tape on the grid (mandatory for 25 mm tile) you get an air leakage rate of less than 0.5m³/h/ m²/Pa under a pressure range of 5 to 40 Pa. For more information, please contact customer service.
Environment Environment Fully recyclable stone wool
Indoor Environment Indoor Environment A selection of Rockfon products have been awarded the Finnish M1 emission classification for building materials and the Danish Indoor Climate Label for low emission products
Back
Back
Back
Back
Back
Back
Microbiological class M1 fulfilling the requirements of Zone 4 (very high risk) defined by NF S 90-351:2013. Tested with:
- Methicillin Resistant Staphylococcus Aureus (MRSA)
- Candida Albicans
- Aspergillus Brasiliensis
The bactericidal and fungicidal effect of dry steam cleaning meets the requirements of NF EN 14561 (> 5 log10) and NF EN 14562 (> 4 log10), meaning the disinfection is very effective.
Back
Back
Back
Back
Back
Back

Configure your product

This product has 2 variants in different sizes.

01 Edge

02 Size

03 Details

A24

product image
product image
product image
product image
product image
product image
product image
product image
product image
product image
product image

illustration
Visible grid
Select length and width (mm)
Select thickness (mm)
Edge
Dimensions
Thickness

Full range

Edge Dimensions (mm) Thickness (mm) Weight (Kg/m2) Min. suspension height (mm) Recommended installation system  
A24 1200 x 600 25 2,70 0

Sound absorption details

αw 0,80
NRC 0,90
Sound absorption class B
Sound curve
Sound curve

Tile details

Minimum installation height 0 mm

Packaging

Pieces Per Pack 11
Area Per Pack 7,92 m2
A24 600 x 600 25 2,70 0

Sound absorption details

αw 0,80
NRC 0,90
Sound absorption class B
Sound curve
Sound curve

Tile details

Minimum installation height 0 mm

Packaging

Pieces Per Pack 22
Area Per Pack 7,92 m2
Back

Sound absorption details

Sound curve
Sound curve

Tile details

Minimum installation height 0 mm
Easy access -

Packaging

Pieces Per Pack 11
Area Per Pack 7,92 m2
Back

Sound absorption details

Sound curve
Sound curve

Tile details

Minimum installation height 0 mm
Easy access -

Packaging

Pieces Per Pack 22
Area Per Pack 7,92 m2
Back

Downloads

documents

 

 

pdf
Rockfon® MediCare® Air | Datasheet
Rockfon® MediCare® Air | Datasheet

pdf
DoP-RFN-0124-041-5 - Rockfon® MediCare® Air
DoP-RFN-0124-041-5 - Rockfon® MediCare® Air

pdf
Back

Find us and our partners

Show

Showing
Offices & Factories near you